Troubleshooting
8-11
Part 1120130
E 2011 Nordson Corporation
Table 8-5 Motor Drive Parameter Factory Settings
Code Pr. Description Setting Note
drC UFt Type of voltage/frequency ratio
L
n SN1710 pump(s) only
SEt UFr lr Compensation/Voltage Boost 5
SEt SLP Slip compensation 35 SN1710 pump(s) only
SEt HSP High Speed 102
drC bFr Standard Motor Frequency 50
drC Uns Nominal Motor Voltage on Name Plate 230
drC FrS Nominal Motor Frequency on Name Plate 102
drC nCr Nominal Motor Current on Name Plate 2.7
drC nsP Nominal Motor Speed on Name Plate 1350
drC nrd Random Switching Frequency No
drC SFr Switching Frequency 4.0
drC tFr Maximum Output Frequency 102
1-0 tCC 2 Wire/3 Wire Control 2C
1-0 tCt Type of 2 Wire Control LEL
1-0 AOlt Configuration of Analog Output IOU
1-0 dO Analog/Logic Output OFR
1-0 r2 Relay r2 rUn
CtL Fr1 Configuration Reference 1 AI1