Troubleshooting
8-12
Part 1120130
E 2011 Nordson Corporation
Troubleshooting Tables
Melter Not Functioning
Possible Cause Possible Fault / Troubleshooting Corrective Action
1. No line voltage Connect line voltage
2. Main power switch
not switched on
Place main power switch in ON
position
3. Main power switch
defective
Replace main power switch
4. Main circuit breaker
activated
Switch on main circuit breaker
5. Main circuit breaker
activated again
Check for short circuit in melter or
accessories
6. 24 VDC power supply
defective
Replace
7. Frequent melter
shutdown
Electromagnetic compatibility
disruptions
Add mains filter
One Channel (Heating Zone) Does Not Heat
Possible Cause Possible Fault / Troubleshooting Corrective Action
1. Channel is disabled /
switched off
Enable / switch on