Technical Data
10-2
Part 1120130
E 2011 Nordson Corporation
Electrical Data
WARNING! The unit is designed for only one operating voltage. Operate
only at the operating voltage shown on the ID plate.
Available operating
voltages
400 V
AC
3‐phase with neutral (star — WYE)
Maximum melter
power requirements
One/two-pump melter Two hose/applicator
15L:8380W
30L:9482W
50L:12420W
Four hose/applicator 15L:12053W
30L:13155W
50L:16094W
Six hose/applicator 15L:13890W
30L:14992W
50L:17931W
Two-pump melter Eight hose/applicator 30L:23166W
50L:25232W
Three/four-pump
melter
Four hose/applicator 30L:18684W
50L:20750W
Six hose/applicator 30L:20521W
50L:22587W
Eight hose/applicator 30L:24194W
50L:26161W
Max. load per hose
receptacle (2 chan-
nels), two/four/six/
eight hose/applicator
melters
1000 W, any single hose or applicator
1200 W, any hose/applicator pair
2000 W, sum of hose/applicator pairs 1 and 2
2000 W, sum of hose/applicator pairs 5 and 6
2000 W, any single hose, or applicator 3 or 4
2000 W, any single hose, or applicator 7 or 8
2000 W, hose/applicator pair 3 or 4
2000 W, hose/applicator pair 7 or 8
4000 W, sum of hose/applicator pairs 3 and 4
4000 W, sum of hose/applicator pairs 7 and 8
NOTE: Total external wattage must not exceed 12,000 W.