Configuring and Modifying Temperature, Pump and Melter Settings
6-7
Part 1120130
E 2011 Nordson Corporation
Button Use this to…. Default Range
Inputs/Outputs Enable/Disable and Customize Inputs/Outputs Input:
1. Standby
2. Standby
3. Heater control
4. External zone
1A/1B
Outputs:
1) Ready (heaters)
2) Fault
3) Tank low
N/A
Format/Units Change the Temperature Units, Date and
Time formats.
Date/Time:
Factory
Temp: Celsius
Date:
mm/dd/yy
dd/mm/yy
mmdd
Time: Factory
Temp: Celsius
Fahrenheit
Passwords
Create ‐ Create or modify a password code.
NOTE: First digit cannot be 0.
5000 Min: One digit
Max: 4 digit
Enable/Enabled ‐ Enable or Disable
password protection.
Disabled Disabled
Enabled
Save
Diagnostic
N/A N/A
Display
Brightness/Contrast - Select the brightness
and contrast levels for easy viewing
Brightness: 75%
Contrast: 75%
Brightness: 30,
60, 75, 100%
Contrast: 30,
50, 75, 100%
Screen Saver Delay - Extend the usefulness
of the display
5 minutes Min: 1 minute
Max: 59
minutes
Calibrate Screen ‐ Allows you to improve the
accuracy of your touch with what is being
displayed on the screens.
N/A N/A
Administration
System Reset |Complete - Revert all system,
temperature and pump settings back to factory
defaults.
N/A N/A
Save Diagnostics - Creates and saves all
melter settings, alert/fault messages and
events to the SD Card. You can then take the
SD Card out of the melter and upload the file
from your computer to technical support.
N/A N/A
Reset Password - Enter a Nordson Technical
Support supplied password.
NOTE: You will be prompted to enter a new
password. Once entered, you can then decide
if you want to disable password protection.
N/A N/A
RTD Options - Allows the system to recognize
a different RTD type.
NI120 NI120
PT100