Service
7-5
Part 1120130
E 2011 Nordson Corporation
Changing the Material Type
1. Run the melter until empty.
2. Determine whether the new material may be mixed with the old material.
S May be mixed: Remaining old material can be flushed out using the
new material.
S May not be mixed: Thoroughly purge the unit with a cleaning agent
recommended by the material supplier.
NOTE: Properly dispose of the old material according to local regulations.
Detaching the Exterior Panels
Open the protective panels with a 4 mm Allen key.
On the inside
Fan and Air Filter
The air filters must be cleaned (knocked out) or replaced, depending on dust
accumulation.
Refer to Section 9, Parts, for the filter part number.