Operating Parameters
B-15
Part 1032059B
E 2003 Nordson Corporation
Manual 41-DURABLUE-MA-02
72 Schedules for Tuesday
Description:
Used to select which schedule(s) should be used on Tuesday.
Value:
0 – Remain at last clock transition
1 – Use just schedule 1
2 – Use just schedule 2
3 – Use just schedule 3
4 – Use schedule 1 and 2
5 – Use schedule 2 and 3
6 – Use schedule 1 and 3
7 – Use schedule 1, 2, and 3
Resolution:
1
Default Value:
0
Format:
Use:
Selects the active schedule(s) for the day.
NOTES: If the 0 schedule option is used, the heaters will not turn on
again until the next scheduled heaters on time arrives.
73 Schedules for Wednesday
Description:
Used to select which schedule(s) should be used on Wednesday.
Value:
0 – Remain at last clock transition
1 – Use just schedule 1
2 – Use just schedule 2
3 – Use just schedule 3
4 – Use schedule 1 and 2
5 – Use schedule 2 and 3
6 – Use schedule 1 and 3
7 – Use schedule 1, 2, and 3
Resolution:
1
Default Value:
0
Format:
Use:
Selects the active schedule(s) for the day.
NOTES: If the 0 schedule option is used, the heaters will not turn on
again until the next scheduled heaters on time arrives.