Operating Parameters
B-17
Part 1073401_07
E 2021 Nordson Corporation
65
Schedule 3 Heaters On
Description:
Used to set the time that the clock will turn on the heaters during
schedule 3.
Value:
0000 to 2359, - - - -
Resolution:
1 minute
Default Value:
- - - -
Format:
Hours, Hour: Minute, Minute
Use:
Set the desired time for the heaters to turn on.
To disable this parameter, set the parameter’s value to “- - - -” by
simultaneously pressing both of the right-display scroll keys.
66
Schedule 3 Heaters Off
Description:
Used to set the time that the clock will turn off the heaters during
schedule 3.
Value:
0000 to 2359, - - - -
Resolution:
1 minute
Default Value:
- - - -
Format:
Hours, Hour: Minute, Minute
Use:
To disable this parameter, set the parameter’s value to “- - - -” by
simultaneously pressing both of the right-display scroll keys.
67
Schedule 3 Enter Standby
Description:
Used to set the time that the melter will enter the standby mode during
schedule 3.
Value:
0000 to 2359, - - - -
Resolution:
1 minute
Default Value:
- - - -
Format:
Hour, Hour: Minute, Minute
Use:
Set the time that the applicator will enter the standby mode during
schedule 3.
To disable this parameter, set the parameter’s value to “- - - -” by
simultaneously pressing both of the right-display scroll keys.
Note: Do not set an enter standby time that is outside of the time period
defined by the schedule’s heater on and off time. The melter cannot enter
the standby mode when the heaters are off.