Setup
4-25
Part 1123087_02
3/2014 Nordson Corporation
Table 4‐7 Smart Melt Capability Default and Optional Settings
Button Description Default Setting Optional Settings
Enabled
Smart Melt
Enables or disables the Smart
Melt capability. If the fill system
is inactive for the amount of
time specified for Smart Melt
Time, the Smart Melt capability
reduces the grid temperature
by the number of degrees
entered for Smart Melt
Temperature.
Enabled Disabled
Smart Melt
Temperature
Specifies the number of
degrees by which the grid
temperature will reduce if the fill
system does not activate for the
amount of time specified for
Smart Melt Time
15 °C (25 °F) 0-30 °C (0-60 °F)
Smart Melt Time Specifies how long the fill
system can remain inactive
before the control system
reduces the grid temperature
by the number of degrees
entered for Smart Melt
Temperature
10 (minutes) 5-60 (minutes)