Relieving System Pressure
Before disconnecting any hydraulic fitting or opening any pressurized port,
always complete the following procedure to safely relieve hydraulic pressure
that can be trapped inside the melter, hoses, and applicators.
1. From the Home screen, touch Pump > Pump Control to switch Off the
pump.
2. Trigger the applicators until adhesive no longer flows from the
applicators.
3. Shut off the main air supply to the melter.
NOTE: Be sure to turn on the main air supply after performing the
required service.