ProBlue Fulfill Integrated Fill System
4
Part 1101094_02
E 2012 Nordson Corporation
Modes of Operation
The default mode of operation is the automatic mode. When the melter is
operating in the automatic mode, the fill system tracks the melter ready
signal. When the melter is ready, the fill system is enabled. If the melter
status changes to not ready, then the fill system is disabled.
When the melter is operating in the manual mode, the fill system must be
manually enabled via the control panel or a remote input. The fill system can
only be enabled when the melter is ready. If the melter is placed into standby
when the system is operating in the manual mode, the fill system will be
disabled. The fill system will remain disabled until the melter is again ready
and the fill system is manually enabled via control panel or remote input.
NOTE: If remote inputs are used for fill system operation (Remote
Enable/Disable and Clear Refill Alarm), then the Fill System Enable key on
the control panel will not function.