Troubleshooting
6-11
Part 1120277_01
E 2012 Nordson Corporation
Table 6-4 Pump Operating Variables
Pump LED
Status
Remote
Motor Input
Assigned
(See Note A)
Remote
Motor Input
Status
(See Note B)
Automatic
Pump On
(Parameter 8)
Handgun/
Footswitch
Handgun/
Footswitch
Input
Status
Unit
Ready
Status
Pump Key
Press Status
(See Note C)
Motor
Rotating
Single
green flash,
then off
Not Assigned N/A Disabled Not present N/A No Ignored No
Off Not Assigned N/A Disabled Not present N/A Yes Off No
Green Not Assigned N/A Disabled Not present N/A Yes On Yes
Off Not Assigned N/A Enabled Not present N/A No Off No
Yellow Not Assigned N/A Enabled Not present N/A No On No
Off Not Assigned N/A Enabled Not present N/A Yes Off No
Green Not Assigned N/A Enabled Not present N/A Yes On Yes
Single
green flash,
then off
Not Assigned N/A Disabled Present On/Off No Ignored No
Off Not Assigned N/A Disabled Present On/Off Yes Off No
Yellow Not Assigned N/A Disabled Present Off Yes On No
Green Not Assigned N/A Disabled Present On Yes On Yes
Off Not Assigned N/A Enabled Present On/Off No Off No
Yellow Not Assigned N/A Enabled Present On/Off No On No
Off Not Assigned N/A Enabled Present On/Off Yes Off No
Green Not Assigned N/A Enabled Present On Yes On Yes
Yellow Not Assigned N/A Enabled Present Off Yes On No
Single
green flash,
then off
Assigned On/Off Disabled Not present N/A No Ignored No
Off Assigned On Disabled Not present N/A Yes Off No
Flashing
Green
Assigned Off Disabled Not present N/A Yes On No
Green Assigned On Disabled Not present N/A Yes On Yes
Off Assigned On/Off Enabled Not present N/A No Off No
Off Assigned On/Off Enabled Not present N/A Yes Off No
Yellow Assigned On/Off Enabled Not present N/A No On No
Flashing
Green
Assigned Off Enabled Not present N/A Yes On No
Green Assigned On Enabled Not present N/A Yes On Yes
NOTE A: If any of Parameters 30-39 are set to 3 or 11, then the remote motor input is as signed.
B: If the remote motor input is assigned, then its status is described in this column.
C: “On” means t he pump key was pressed and the unit accepted the key press. “
Ignored” means that the
pump key will not respond to a key press.