Technical Data
8-2
Part 1120277_01
E 2012 Nordson Corporation
Electrical Specifications
NOTE: Refer to Configuring the Electrical Service in Section 3, Installation,
for maximum amperage specifications.
Item
Data
Note
Nominal Allowable Range
Voltage 200-240 VAC 180-264 VAC A
400/230 VAC 312/180-457/264 VAC A, B
Frequency 50/60 Hz
Hose/gun heating capacity 3 hose/gun pairs
Control temperature range
Minimum: 50 _C (120 _F)
Maximum: 20 _C(40_F) below thermostat temperature rating
(176 C [350 F]
C, D
Control temperature accuracy ¦ .5 C(¦ 1 F)
IP rating IP 32
NOTE A: Depends on the melter configuration and the voltage plug installed. Refer to Melter Part Numbers in
Section 7, Parts,andtoMelter Configuration Code later in this section to determine the configuration of
your melter.
B: 400/230 VAC is for electrical service with neutral (WYE) where the 400 VAC is a line-to-line voltage and the
230 VAC is a line-to-neutral voltage.
C: Depends on the melter configuration. Refer to Melter Part Numbers in Section 7, Parts,andtoMelter
Configuration Code later in this section to determine the configuration of your melter.
D: The maximum unit temperature, regardless of thermostat is 190 _C (374 _F).
Heater Specifications
NOTE: Refer to the hose and gun manuals for hose/gun heater
specifications.
Location
Wattage
(see Note A)
Voltage
Cold Resistance
(see Note B)
Manifold 600 240 V 82-96 ohms
Reservoir 2 x 400 240 V 137-160 ohms each
Melt plate 4 x 200 240 V 287 ohms each
NOTE A: Nominal wattage at 177-204 _C (350-400 _F).
B: Measured at room temperature for a previously heated element.