Operating Parameters
B-9
Part 1120277_01
E 2012 Nordson Corporation
23 Standby Delta
Description: The number of degrees by which all heated components will be
decreased when the applicator is placed into the standby mode.
Value: 5 _C to 190 _C(10_F to 350 _F)
Resolution: 1 _C
1 _F
Default Value: 50 _C (100 _F)
Format:
Use: A s tandby delta should be selected that results in a balance
between melter energy savings during periods of inactivity, the
amount of time and energy required to bring the melter back up
to setpoint temperature, and a temperature at which the h ot melt
can be held in the reservoir for extended periods of time without
charring. Refer to Section 4, Operation, Using Melter Function
Keys.
NOTE: The standby delta does not affect the under temperature
delta (parameter 22).
24 Automatic Stand by Timeout
Description: Theamountoftimethatthemeltplatecanstayoff(ascontrolled
by the melt-on-demand function) before the melter is placed in
standby. Automatic Standby Timeout protects the PUR adhesive
from unnecessary heat exposure when the melter is not in use.
Value: 30 to 1440 minutes
Resolution: 1minute
Default Value: 180 (minutes)
Format:
Use: 1. Change parameter 23 if required.
25 Automatic H eaters Off Time
Description: The amount of time that must elapse after the automatic standby
time elapses (parameter 24) before the heaters turn off.
Value: 0 to 1440 minutes (24 hours)
Resolution: 1minute
Default Value: 0(disabled)
Format:
Use: Set parameter 24 (automatic standby timeout) to the desired
value before s etting parameter 25.