Operating Parameters
B-10
Part 1120277_01
E 2012 Nordson Corporation
Temperature Control (contd)
26 Manual Stand by Time
Description: The amount of time that the melter will remain in the standby
mode after the standby key is pressed.
Value: 0 to 180 minutes
Resolution: 1minute
Default Value: 0
Format: —
Use: Setthestandbytimewhenyouwanttheoperatortobeableto
place the melter into the standby mode for a limited period of
time(break,lunch,etc.).Whenmanualstandbyisenabled
(value greater than 0 minutes), the standby LED blinks.
Set the standby delta (parameter 23) to the desired value before
setting parameter 26.
NOTE: When a time value equal to or greater than 1 minute is
entered, the standby LED will flash to indicate that the manual
standby timer is counting down.
27 Hose Standby Delta
Description: The number of degrees by which all heated hoses will be
decreased when the applicator is placed into the standby mode.
Value: 1 _C to 190 _C(1_F to 350 _F)
Resolution: 1 _C
1 _F
Default Value: 0
Format: —
Use: This parameter functions like parameter 23 except when it is set
to 0, in which case it reverts to the setting for parameter 23.
NOTE: The standby delta does not affect the under temperature
delta (parameter 22).
28 Gun Standby Delta
Description: The number of degrees by which all heated guns will be
decreased when the applicator is placed into the standby mode.
Value: 1 _C to 190 _C(1_F to 350 _F)
Resolution: 1 _C
1 _F
Default Value: 0