Operating Parameters
B-25
Part 1120277_01
E 2012 Nordson Corporation
Seven-Day Clock (contd)
61 Schedule 2 Heater s Off
Description: Used to set the time that the clock will turn off the heaters during
schedule 2.
Value: 0000 to 2359, ----
Resolution: 1e
Default Value: ----
Format: Hours, Hour: Minute, Minute
Use: Todisablethisparameter,settheparameter'svalueto“----”by
simultaneously pressing both of the right-display scroll keys.
62
Schedule 2 Enter Standby
Description: Used to set the time that the melter will enter the standby mode
during schedule 2.
Value: 0000 to 2359, ----
Resolution: 1minute
Default Value: ----
Format: Hour,Hour:Minute,Minute
Use: Set the time that the applicator will enter the standby mode
during schedule 2.
Todisablethisparameter,settheparameter'svalueto“----”by
simultaneously pressing both of the right-display scroll keys.
NOTE: Do not set an enter standby time that is outside of the
time period defined by the schedule's heater on and off time.
The melter cannot enter the s tandby mode when the heaters are
off.
63 Schedule 2 Exit Standby
Description: Used to set the time that the melter will exit the standby mode
during schedule 2.
Value: 0000 to 2359, ----
Resolution: 1minute
Default Value: ----
Format: Hour,Hour:Minute,Minute
Use: Set the time that the applicator will exit the standby mode during
schedule 2.
Todisablethisparameter,settheparameter'svalueto“----”by
simultaneously pressing both of the right-display scroll keys.
NOTE: Do not set an exit standby time that is outside of the t ime
period defined by the schedule's heater on and off time. The
melter cannot enter the s tandby mode when the heaters are off.