Operating Parameters
B-31
Part 1120277_01
E 2012 Nordson Corporation
Automatic Fill Timer
78 Automatic Fill Timer
Description: A count-down t imer that can be associated with a switch
connected to an input.
Value: 0to99seconds
Resolution: 1
Default Value: 0 (Disabled)
Format:
Use: Used in conjunction with input control option 13 or 14. Enable
output control option 6, Alert, to send a signal when the timer
expires.
PID Selection
80-87
PID Selection for Hose/Gun Receptacles 1, 2, 3,
and 4
Description: Used to change the preset PID selections. Use parameter 80 to
select the value for hose 1, parameter 81 to select the value for
gun 1, and so on, up to hose 4/gun 4.
Value: 0=Hose
1=Standardgun
2=Largegun
3=Airheater
Resolution:
Default Value: 0 or 1 depending on the channel type (hose or gun)
Format:
Use: Consult your Nordson representative before changing PID
settings.
88 - 91
PID Selection for Hose/Gun Receptacles 5, 6, 7,
and 8 (DuraBlue D25, D50, and D100 melters only)
Description: Used to change the preset PID selections. Use parameter 88 to
select the value for hose 5, parameter 89 to select the value for
gun 5, and so on, up to hose 8/gun 8.
Value: 0=Hose
1=Standardgun
2=Largegun
3=Airheater
Resolution:
Default Value: 0 or 1 depending on the channel type (hose or gun)
Format:
Use: Consult your Nordson representative before changing PID
settings.