EasyManua.ls Logo

Nordson PURBlue 4 - Installation Requirements; Clearances

Nordson PURBlue 4
250 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation
3-4
Part 1120277_01
E 2012 Nordson Corporation
Installation Requirements
Before installing the melter, ensure that the desired installation location
provides the required clearances, environmental conditions, and utilities.
Clearances
Figure 3-1 illustrates the minimum clearances that are required between the
melter and surrounding objects. Table 3-1 describes each clearance. For all
melter dimensions, refer to Section 8, Technical Data.
Table 3-1 Minimum Installation Clearances
Item Description
Required
Clearance
A
Clearance required between the back of
the melter and the nearest object
150 mm (5.9 in.)
B
Clearance required between the front of
the melter (control panel) and the
nearest object in order to fully open the
electrical enclosure door
252 mm (9.9 in.)
C
Minimum horizontal space required to
open the electrical enclosure door
137 mm (5.4 in.)
D
Minimum horizontal space required to
remove the service cover
290 mm (11.4 in.)
E
Depth of melter including service
handles
678 mm (26.7 in.)
F
Minimum vertical space required for the
melter if mounting feet are not used
964 mm (37.9 in.)

Table of Contents