Installation
3-13
Part 1120277_01
E 2012 Nordson Corporation
Table 3-3 Electrical Service Information
Use Electrical Connector
Terminals..
Use Voltage Plug..
If the Electrical Service Type is.. L1 L2 L3 N
400/230 VAC 3-phase
(4-wire service, including a
neutral) (See Note A)
3/N/PE AC
400/230V
227569
Red/Yellow
230 VAC 1-phase
(2-wire service, including a
neutral) (See Note A)
1/N/PE AC
200–240V
232617
Blue/Yellow
200-240 VAC 3-phase (3-wire
service without a neutral)
3/PE AC
200–240V
227568
Red/Green
200-240 VAC 1-phase (2-wire
service without a neutral)
1/PE AC
200–240V
227567
Blue/Green
NOTE A: The 400/230 VAC 3-phase service (4-wire service including neutral) includes the 415/240 VAC 3-phase
(4-wire service, including neutral) voltage. The 230 VAC 1-phas e service (2-wire service, including a neutral)
includes the 240 VAC 1-phase (2-wire service, including a neutral) voltage.