Installation
3-25
Part 1120277_01
E 2012 Nordson Corporation
7. Press the Enter key.
The melter checks that the new value or control option is acceptable.
S If the numeric setpoint or control option is accepted, the left and right
displays index to the next sequential parameter number and value.
S If the numeric setpoint or control option is not accepted, the right
display will indicate dashes (----) for three seconds and then it will
change back to the original value.
8. Repeat step 5 through step 7 to read or change the next sequential
parameternumberorpresstheSetup key to exit the setup mode.
Table 3-6 Operating Parameters
Parameter Name Range of Values Default Value
Standard
0 Enter Password 0 to 9999 4000
1 Total H ours with Heaters On
(noneditable)
0 to 9999 0
2 Fault Log (noneditable) _-F0 (empty)
3 Change History Log (noneditable) P-_ (empty)
4 Ready Delay Time 10 to 60 minutes 15 minutes
5 Service Interval Time 0 to 8736 hours 500 hours
6 Service LED Heater Hours 0 to 9999 hours 0
7 Motor Off Delay 0 to 360 seconds 0seconds
8 Automatic Pump On 0 (disabled) or 1 (enabled) 1(enabled)
10 Enable or Disable Password 0 (disabled) or 1 (enabled) 0(disabled)
11 Create Password 0 to 9999 5000
12
Change Hose 1 Output to Electric Gun
Activation
0 (disabled) or 1 (enabled) 0(disabled)
13
Change Hose 2 Output to Electric Gun
Activation
0 (disabled) or 1 (enabled) 0(disabled)
14 External Communications Lock-out 0or1 0(disabled)
Continued...