Installation
3-37
Part 1120277_01
E 2012 Nordson Corporation
Table 3-8 Digital Input Data
Input Terminals Operating Parameter Control Option Note
Standard Inputs
1 8and9 30
0 - Input Disabled (Default)
1 - Standby On/Off
2 - Heaters On/Off
3 - Motor 1 Enable/Disable
4 - Hose/Gun 1 Enable/Disable
5 - Hose/Gun 2 Enable/Disable
6 - Hose/Gun 3 Enable/Disable
7 - Hose/Gun 4 Enable/Disable
8 - Hose/Gun 5 Enable/Disable
9 - Hose/Gun 6 Enable/Disable
11 - Motor 2 Enable/Disable
13 - Automatic Fill Timer No. 1
14 - Automatic Fill Timer No. 2
A
2 10 and 11 31 Not available
3 12 and 13 32 Not available
4 7and14 33
Same as parameter 30 (except for control option 10,
which is not available) (Default=0)
Optional Inputs
5 11 and 12 34 Same as parameter 33 (Default=0) B, C
6 13 and 14 35 Same as parameter 33 (Default=0) B, C
7 15 and 16 36 Same as parameter 33 (Default=0) B, C
8 17 and 18 37 Same as parameter 33 (Default=0) B, C
9 19 and 20 38 Same as parameter 33 (Default=0) B, C
10 9and10 39 Same as parameter 33 (Default=0) B, C
NOTE A: If control option 3 is selected, the motor will not turn on—even if you pres s the pump enable key—if
voltage is not present on the input's contacts.
B: Parameters 34 through 39 are reserved for the inputs created when either the optional I/O expansion
card or optional I/O board is installed. Refer to Appendix B, Operating Parameters, for more information.
C: Refer to the instruction sheet provided with the optional I/O expansion card or analog I/O board for wiring
information.