Output connector P/N 277908
Installation
3-39
Part 1120277_01
E 2012 Nordson Corporation
SeeFigure3-10.
2. Connect each pair of output wires to the appropriate terminals
(1 through 7) on connector P/N 277908. The connector is provided in the
installation kit. Table 3-9 lists the terminal numbers that correspond to
each output.
NOTE: Terminal number 7 on connector P/N 277908 is reserved for
input number four. Connector P/N 277908 is physically keyed to prevent
it from being used as connector P/N 277909, which has terminals
numbered 8 through 14.
3. Plug connector P/N 277908 into the top receptacle on terminal XT7,
which is located on the expansion board.
XT7
Figure 3-10 Wiring outputs
To set up a digital output
Set up the parameter control option for each output that you connected to the
melter. Table 3-9 lists the available control options. Refer to Setting Up the
Melter earlier in this section for i nformation about how to select operating