Nordson PURBlue 4 - Flow Control Bypass (F Option); Placing the System in Standby

Nordson PURBlue 4
250 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Location of the air regulator and
gauge used with the flow control
bypass option
Standby key
Operation
4-9
Part 1120277_01
E 2012 Nordson Corporation
Flow Control Bypass (F Option)
If no signal is being supplied to the solenoid valve, use the air pressure
regulator located on the F option drive cover assembly to adjust the output
pressure to the pneumatic PCV. The gauge on the drive cover displays the
air pressure provided to the pneumatic PCV.
NOTE: If a signal is being provided to the solenoid valve, the output
pressure to the pneumatic PCV corresponds to the melter supply pressure.
Placing the System in Standby
To keep reactive materials from curing, perform the following actions before
downtime or breaks:
1. Press the Standby key to reduce the system temperature and place the
system in standby mode.
2. Cover the applicator nozzles with petroleum jelly or submerge them in a
suitable oil.