Operation
4-21
Part 1120277_01
E 2012 Nordson Corporation
Table 4-2 Fault Log
First Digit Second and Third Digits Fourth Digit
Component:
-F
Type of fault:
0=Reservoir 0=Unusedlogentry
1=Pumporhose/gun1 1 = RTD (open or short)
2 = Melt plate or hose/gun 2 2 = Component under
temperature
3=Hose3orgun3 3 = Component over temperature
4 = Processor or electrical failure
Fault Log Examples
Example 1:
An unused log entry.
Example 2:
If the LED on the reservoir key were on, this log entry
would indicate that the reservoir is under temperature. If the LED on the hose
key were on, this log entry would indicate that hose 1 is under temperature.
Monitor Motor/Piston Control or Motor Drive Faults
Thepumpspeeddisplayandthedisplayonthemotordrivelocatedinside
the electrical enclosure alert the operator to abnormal motor/piston-related
faults. These faults may cause the pump to stop. Refer to Motor/Piston
Control Faults or Motor Drive Faults in Section 6, Troubleshooting.