Repair
7-11
P/N 7135268B
E 2008 Nordson Corporation
PURBlue EC
Reservoir
Fig. 7-11 Reservoir
Installing Service Kit
The kit contains the temperature sensor for the reservoir and heat transfer
compound.
Service kit P/N: 394597 (Ni120)
Required tools:
Pliers
Side cutting pliers
1. Remove electrical equipment cover.
2. Disconnect connecting wires and extract old temperature sensor by the connecting wires or with the
aid of a pliers.
3. Apply heat transfer compound to new sensor.
4. Insert sensor and reconnect electrically.
5. Attach electrical equipment cover again.