Technical Data
9-1
P/N 7135268B
E 2008 Nordson Corporation
PURBlue EC
Section 9
Technical Data
General Data
Storage temperature
− 45°C to + 75 °C − 49 °F to + 167 °F
Min. ambient temperature
− 5 °C 23 °F
Max. ambient temperature
40 °C 104 °F
Humidity 10 to 95 %, not condensing
Max. operating height
above sea level
3,000 m 9840 ft
Type of heating Heater cartridges (grid and reservoir / heating plate) +
band heater (hopper)
Temperature sensor Ni 120
− Measuring precision
" 1 °C
Material pressure (standard) The pressure control valve is preset at the factory. Default:
35 bar 3500 kPa 508 psi
Degree of protection IP 54
Noise emission
at a distance of 1 m
1 motor: 62 dB(A)
Motor type 3 ph AC motor
Gear box type Helical gear
Motor/pump speed setting
range
1.0 to 100 min
-1
To prevent excessive wear, the motor/pump speed should not continuously
fall below 5 min
-1
(rpm) or continuously exceed 80 min
-1
(rpm).
Heatup time <45 min
Melting capacity 20 kg per hour