Operating Parameters
B-1
P/N 7135268B
E 2008 Nordson Corporation
PURBlue EC
Appendix B
Operating Parameters
Parameter Groups - Overview -
NOTE: Reserved parameters do not appear in this appendix.
Group Parameter Description
Standard
Pressure
Temperature
0 to 26
15 to 17
20 to 26
Frequently used parameters
Input setup 30 to 39 Select function for input 1 to 4 and optional inputs
Output setup 40 to 46 Select function for output 1 to 3 and optional outputs
Seven-day clock 50 to 77 Seven-day clock setup
Automatic filling 78 Set timer for automatic filling
Reversal of fault logic 79 Select contact opens or closes when fault occurs
PID selection 80 to 91 Change control parameters
Restore Melter Default Settings
1. Press and hold Setup and the scroll key Page down at the same time.
2. Keep the keys pressed and, at the same time, switch the main switch of
the melter off and then on again.
3. Release the keys when the melter restarts.
CAUTION: Defaults are dependent on the software. The Original state
depends on the melter. Some parameters may differ from the Default.
Original State
The operating parameters and setpoint temperatures have been adapted for
PUR processing. The original state was saved.
Refer to Save and Restore Settings in the section Operation.