Desktop symbol NCM
Melter Communication
C-4
P/N 7135268B
E 2008 Nordson Corporation
PURBlue EC
Using Nordson Configuration Manager
The Configuration Manager is started from the Windows desktop by clicking
on the symbol shown at left.
Saving Melter Settings
When the settings are saved, the current setpoint temperatures and
operating parameter values are copied onto your PC.
1. Put the melter in setup mode. Do this by simultaneously pressing the
Standby key and the Setup key.
COnF” appears in the right display.
2. Double click on the NCM symbol on the Windows desktop.
The Configuration Manager dialog box appears.
3. Click on Select Device.
The Select Product dialog box appears.
4. Select DuraBlue from the list, then click on OK.
The Select COM Port dialog box appears.
5. Select the COM port used for the connection to the melter, then click on
OK.
The PC and the melter establish communication, and an image of the
selected melter appears in the melter status area. The right side of the
status area indicates CONNECTED.
6. Click on Save Settings.
The Save As dialog box appears.
NOTE: The default storage location for the settings files is the Windows
folder My Documents. To avoid losing saved settings files, Nordson
recommends not to change the default storage location.