Introduction
2-6
P/N 7135268B
E 2008 Nordson Corporation
PURBlue EC
Tank
The tank is divided into hopper (tank extension) with band heater, grid
(melting plate) and reservoir (high melt) sections. The different heating
zones allow the material in the hopper (1) to be gently melted at a low
temperature. The material is then heated to processing temperature in the
grid (2) and reservoir (3).
The tank can be tilted and dismantled for cleaning purposes (Refer to
section Maintenance, Tank).
Fig. 2-6
Cable Glands
2
1
Fig. 2-7 Back wall of electrical cabinet
1 Cable gland Melter inputs/outputs
and KTL
2 Cable gland Power supply
Melter Inputs/Outputs
For communication between the parent machine and the Nordson melter.