Installation
3-11
P/N 7135268B
E 2008 Nordson Corporation
PURBlue EC
Standard Outputs
All of the output contacts are intended for 240 V
AC
2 A or 30 V
DC
2 A.
All contacts are open when the melter is switched off.
Refer to Appendix B for all possible control options.
Output
(standard)
Operating parameter Control option
(original state)
Plug connector and
terminal
1
40
1: Ready P/N 277908
1 and 2
2
41
0: Output disabled P/N 277908
3 and 4
3
42
0: Output disabled P/N 277908
5 and 6
NOTE: Connector P/N 277908 is physically keyed to prevent it from being
used in place of connector P/N 277909, which has terminals numbered 8
through 14.
P/N 277908
1234567
XT7
Fig. 3-10 I/O expansion board − installing outputs