Technical Data
9‐1
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Section 9
Technical Data
General Data
Storage temperature - 45°C to + 75°C - 49°F to + 167°F
Min. ambient temperature - 5°C 23°F
Max. ambient temperature 40°C 104°F
Humidity 10 to 95 %, not condensing
Max. operating height 3,000 m 299,923.20 cm
Type of heating Cast-in electrical resistance heating elements
Possible temperature
sensors
Ni120 (standard melter)
Pt100 (high temperature melter)
- Measuring precision ±1°C
Material pressure
(standard)
5 to 85 bar 500 to 8500 kPa 72.5 to 1 233 psi
The pressure control valve is preset at the factory. Default:
35 bar 3500 kPa 508 psi
Degree of protection IP 54
Noise Emission
at a distance of 1 m
1 motor: 62 dB(A)
2 motors: 65 dB(A)
Motor type 3 ph AC motor
Gear box type Helical gear
Motor/pump speed setting
range
1.0 to 100 min
-1
To prevent excessive wear, the motor/pump speed should not continuously
fall below 5 min
-1
(rpm) or continuously exceed 80 min
-1
(rpm).
Heatup time < 45 min (standard melter)
< 60 min (high temperature melter)
Melting capacity 1 tank full per hour