EasyManua.ls Logo

Nordson VersaBlue VA - Technical Data; General Data

Nordson VersaBlue VA
272 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Data
9‐1
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Section 9
Technical Data
General Data
Storage temperature - 45°C to + 75°C - 49°F to + 167°F
Min. ambient temperature - 5°C 23°F
Max. ambient temperature 40°C 104°F
Humidity 10 to 95 %, not condensing
Max. operating height 3,000 m 299,923.20 cm
Type of heating Cast-in electrical resistance heating elements
Possible temperature
sensors
Ni120 (standard melter)
Pt100 (high temperature melter)
- Measuring precision ±1°C
Material pressure
(standard)
5 to 85 bar 500 to 8500 kPa 72.5 to 1 233 psi
The pressure control valve is preset at the factory. Default:
35 bar 3500 kPa 508 psi
Degree of protection IP 54
Noise Emission
at a distance of 1 m
1 motor: 62 dB(A)
2 motors: 65 dB(A)
Motor type 3 ph AC motor
Gear box type Helical gear
Motor/pump speed setting
range
1.0 to 100 min
-1
To prevent excessive wear, the motor/pump speed should not continuously
fall below 5 min
-1
(rpm) or continuously exceed 80 min
-1
(rpm).
Heatup time < 45 min (standard melter)
< 60 min (high temperature melter)
Melting capacity 1 tank full per hour