Installation
3‐7
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Connecting Hose
Also refer to the hose manual.
Connecting Electrically
1. First connect the hose (1) electrically to the unit.
Use hose receptacles XS10 to XS17 (2b) for the plugs (2a) of the hoses. The
connections are protected with a clamp.
NOTE: For more than one hose: Every hose connection is allocated to a
corresponding receptacle. Do not mistakenly exchange!
Refer to wiring diagram for connecting arrangement.
2a
1
2b
2a
Fig. 3‐7 Connecting electrically (example Ni120)
Connecting
Second Open-end Wrench
Use a second open‐end wrench when connecting and disconnecting the
hose. This prevents the melter's hose connection from turning.
Continued ...