EasyManua.ls Logo

Nordson VersaBlue VA - Interface Assignment XS4: Bypass Control

Nordson VersaBlue VA
272 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation
3‐17
P/N 213828_11
2014 Nordson Corporation
VersaBlue_PPA
Pneumatic Pressure Control / Bypass Control (contd.)
Interface Assignment XS4: Bypass Control
PIN Input Function
1
24 V
DC
/
4 W
Pneumatic pressure control valve 1
2
3
24 V
DC
/
4 W
Pneumatic pressure control valve 2
4
Solenoid Valve and Timer Relay
An additional solenoid valve (P/N 401116: ‐164Y8) in the air supply is linked
to the signal System ready. Wiring diagram page SLP 164b.
The timer relay -164K6 is located in the left door of the electrical cabinet.
Approx. 3 s switchon delay (timer relay P/N 7157900)
M
Solenoid valve
Electrical signal
Applicator
open
Applicator
closed
Pressure controller
Nozzle
Hose
MotorPump
Filter
Tank
Applicator
Compress
e
Pneumatic
pressure control
valve
Pressure display
‐205Y2
-164Y8
Fig. 3‐15 Option F: Bypass control (1 pump)

Table of Contents