After the melter has been properly installed, initial startup can take place.
Purging Melter
The melter was subjected to extensive testing prior to shipment. In doing so,
the tank was filled with a special test material. Material residue may still be
present in the melter. To remove the residue, melt and feed several
kilograms of material before starting production.
CAUTION: Do not operate Nordson gear pumps without material. Before
switching on the motor, ensure that the tank is filled.
1. Fill the tank (Refer to Filling the Tank).
2. Set the main switch to I/ON. The melter begins to heat up.
Automatic heatup upon daily startup can be prevented with the buttonAutomatic
heatup ... when the software version is 6.00.000 or higher.
Position I/ON = Melter switched on.
Position 0/OFF = Melter switched off.
Padlocks can be used to protect the main switch from being turned on by
unauthorized personnel.
During booting, the PC performs a function test to verify that all
touch-sensitive areas are OK.
NOTE: Direct sunlight on the control panel can potentially trigger the fault
indication. Please clean the screen.