checkedwithoutidentifyingthe causeof the
problem,pressthe red resetbuttonson the
ventsafetyandtherolloutlimitswitches.(See
Fig-ure1).
IMPORTANT: If the furnace operates after
depressing the reset button on the vent
limit or roll out limit, it is an indication of a
potentially serious problem in the installa-
tion. Follow the instructions "To Turn Off
Gas To the Appliance" located in these
instructions or on the door of the furnace.
Contact a qualified serviceman to identify
and repair the problem.
MANUFACTURER WARRANTY, OWNER
RESPONSIBILITIES
It is the sole responsibility of the homeowner to
make certain the gas furnace has been cor-
rectly set up and adjusted to operate properly.
NORDYNE warrants this furnace to be free
from defects in material or workmanship for a
period of one year. A warranty certificate with
full details is included with this document. How-
ever, NORDYNE will not be responsible for any
costs found necessary to correct problems
due to improper setup, improper installation,
furnace adjustments, improper operating pro-
cedure on the part of the user, etc.
Some specific examples of service calls which
cannot be included in warranty payments are:
1. Converting the furnace to use another type
of gas.
2. Repairing duct work in the home found to be
faulty.
3. Correcting wiring problems in the electrical
circuit supplying the furnace.
4. Resetting circuit breakers, blown fuses or
other switches.
5. Correcting problems due to improper gas
supply pressure to the furnace.
6. Providing instructional training on how to
light and operate the furnace.
7. Correcting any problems caused by installa-
tion of an air conditioner, heat pump or other
air comfort devices.
8. Revising installation of the furnace flue as-
sembly.
9. Adjusting or calibrating of thermostat.
10. Removing any construction debris which
has fallen into flue system.
Carefully review these responsibilities with your
dealer, service company, or gas supplier so
there will be no misunderstanding at a later time.
Read Your Warranty
Please read your limited warranty completely. It
contains valuable information about your fur-
nace. If you have any questions about the
warranty information, contact your NORDYNE
distributor.
MAINTENANCE ITEM
FREQUENCY OF MAINTENANCE
MONTHLY
VERIFY FURNACE AREA IS FREE
OF COMBUSTIBLE MATERIALS X
VERIFY COMBUSTION AND VENTILATION
AIR IS NOT RESTRICTED X
VERIFY NO SIGNS OF PHYSICAL
DETERIORATION OF THE FURNACE X
VERIFY NO OBSTRUCTIONS OR
RESTRICTIONS IN VENT OR CHIMNEY
VERIFY NO HOLES OR CRACKS IN VENT PIPE
VERIFY NO CORROSION IN VENT PIPE
VERIFY THAT HORIZONTAL VENT PIPES
SLOPE UPWARDS AWAY FROM FURNACE
VERIFY BURNER FLAME
CLEAN OR REPLACE FILTER(S) X
CLEAN BLOWER COMPARTMENT X
CLEAN BURNER ASSEMBLY X
Table 1. Maintenance Table
7
BEGINNING OF
EACH HEATING SEASON
x
x
x
x
x
x
x
x
END OF EACH
HEATING SEASON
x
x
x
x
x
x
x