EasyManua.ls Logo

Noritz EZTR50 - Heat Exchanger Assembly and Rejoining; Replace Primary SS HEX

Noritz EZTR50
23 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Heat Exchanger Replacement Procedure
Diagram
11.Replace Primary SS HEX
(1) Attach Water Connector - Elbow and "C" Clamp
to new Primary SS HEX.
In that case, exchange O ring - High Temp P16 of
Water Connector - Elbow for a new one.
(NCC199CDV ONLY)
Attach Pipe - Primary SS HEX Connection
with 2 "C" Clamps to new Primary SS HEX.
In that case, exchange O rings - High Temp P16 of
Pipe - Primary SS HEX Connection for new ones.
(2) Only EZ111DV/EZ98DV or NCC199CDV
Attach 2 Freeze Prevention Heaters to new
Primary SS HEX with 2 Clamps.
(3) Exchange 2 Gasket - Primary Heat Exchangers
for new ones.
12.Join Primary SS HEX and Burner Chamber
(1) Peel off old Gasket- Burners and replace it
with new Gasket - Burner.
Page 13
Procedure
(1)
(1)
EZ111DV
(3)
e.g. EZ111DV
(2)
NC199CDV
(1)
Attach in the center of the line