4 6-050700 X2
212iLW & 242iLW Standalone Keypad
Installation & Programming Manual
2. Specifi cations
Parameter Range/Description
Voltage 10–30 VDC, 12-24 VAC (Auto-Adjusting)
Current
93 mA @ 10 VDC; 158 mA @ 30 VDC,
148 mA @ 12 VAC; 198 mA @ 24 VAC
242 Model - Add 25 mA for each energized aux
relay (max = 75 mA)
Environment For Indoor and Outdoor Use
Temperature Tolerance -20° F to 130° F (-28° C to 54° C)
Dimensions 5-1/8" H x 3-3/8" W x 5/8" D
Main Relay (Form C) Contact Rating: 2 A @ 30 VAC/DC
Aux Relay (Form C) Contact Rating: 1 A @ 24 VAC/DC
REX Input Normally Open Dry Contact
Door Position Input Normally Closed Dry Contact
LEDs Bi-Color Red/Green; Yellow
Default Keypad Settings
Parameter Default Setting
Master Code 1234
Lock Output Relay 1 (Main relay – 212 and 242)
Alarm Shunt Output Relay 2 (242)
Propped Door Output Relay 3 (242)
Forced Door Output Relay 4 (242)
Audio Alerts Not Assigned (212 and 242)
REX Triggers Lock Output
REX Operation Always Triggers (regardless of Door Loop)
Error Lockout Enabled
Error Lockout Threshold 3 Attempts
Error Lockout Duration 10 Seconds
Lock Output Time 5 Seconds
Propped Door Output Time 30 Seconds
Forced Door Output Time 10 Seconds
Visual Keypress Feedback Enabled
Audio Keypress Feedback Enabled
Auto-Entry Disabled
User Lockout Enabled