GC2e Wireless Security System | Installation and Programming Guide
©2020 Nortek Security & Control LLC. All rights reserved. 40 2GIG is a registered trademark of Nortek Security & Control LLC.
• For automac entry. Tap Shi, then tap Learn to place
the Control Panel into learning mode. Then trigger the RF
sensor. The Control Panel will beep four (4) mes and learn
the sensor’s serial number. If the sensor being learned is
already in memory, the Control Panel will display a sensor
learning failure screen when the programming changes are
being saved.
For certain sensors with more than two loops, the tamper switch
must be used to send a signal to the Control Panel during sensor
learning. The r st press of the tamper switch will learn the sensor
into the panel as Loop #1. The second press of the tamper switch
will learn the sensor into the panel as Loop #2, and the third press
of the tamper switch will learn the sensor into the panel as Loop
#3. Pa use 15 seconds between each press of the tamper switch.
The programmed loop number of the sensor in the Control Panel
may need changing to suit the operaon of the device. For details,
see the Installaon Instrucons included with the sensor.
Q: Select RF Sensor # Equipment Age (0 to 1)
DEFAULT: (0) New
The Control Panel can be used with new or exisng RF sensors.
• If this RF sensor is new for the installaon, leave the default
seng of (0) New.
• If this RF sensor is already installed, select (1) Exisng.
NOTE: If the RF sensor has more than one loop and is being
programmed into mulple sensor numbers to support the loops,
set only one loop as “new” and the other loops as “exisng”. This
will prevent incorrect inventory of the installed sensors.
Q: Select RF Sensor # Loop Number (1 to 3)
DEFAULT: Varies with sensor model selected
The 2GIG Door/Window Contact sensors have two (2) inputs: an
internal magnec contact and an external Normally Closed (N/C)
hardwired input. Either or both sensor inputs can be used.
TIP: Some sensors are capable of three (3) loop inputs.
NOTE: When using both the internal magnec contact and the
external input, the magnet contact AND the external contact must
be assigned a dierent RF sensor number. Both sensor numbers
will share the same sensor serial number.
• When programming the sensor to use the built-in magnec
contact, set the loop number to (2) 2.
• When programming the sensor to use its hardwired input,
set the loop number as (1) 1.
• When programming a three (3)-loop sensor to use an
addional input, set the loop number as (3) 3.
• When entering the sensor number for the sensor’s loop 2
or 3, tap Paste to recall the last programmed sensor’s serial
number. (The sensor number will be lled in automacally
if Learn is used).
Q: Select RF Sensor # Dialer Delay (0 to 1)
DEFAULT: (1) Enabled
If this feature is enabled, the delay me must be set to a minimum
of 30 seconds for ANSI/SIA compliance. To set the delay me, see
“Q35: Abort Window Dialer Delay (0-2)” on page 52.
• RF sensors can trigger the digital communicator
immediately or aer a delay. The default seng (1) Enabled
causes delayed dialing for this RF sensor number.
• For immediate dialing for this RF sensor number, select (0)
Disabled.
NOTE: This seng for CO and Smoke Alarms is automacally set
to (0) Disabled, and this sub-queson is skipped for these sensor
types.
Q: Select RF Sensor # Equipment Type
DEFAULT: Varies by RF Sensor Type
NOTE: Some sensor types (zones) will require you to specify an
equipment type selecon, which aects the sensor’s extended
reporng code.
Simply enter the appropriate equipment type code (see table below)
or tap the ← or → arrows to select the appropriate equipment type.
The table below shows the Equipment Types available for each Sensor
Type (Zone):
Q: Select RF Sensor # Equipment Code
DEFAULT: (0000) Other
Select the four (4)-digit equipment code that corresponds to the
appropriate sensor model. See “Equipment Codes” on page 37.
• When programming eSensors (Wireless & Keyfobs), the
equipment code must match the sensor being installed.
Q: Select RF Sensor # Other Equipment Code
NOTES:
• This sub-queson is only displayed if (0000) Other is selected as
the RF Sensor # Equipment Code.
Enter the equipment code number directly on the keypad for the RF
sensor. Enter “0” if the new equipment code is unknown.
Q: Enter RF Sensor # Serial Number (7 Digits)
DEFAULT: 0000000
RF sensor serial numbers can be manually entered or automacally
transmied from the sensor to the Control Panel.
• For manual entry. Enter the sensor number that was logged
for the sensor being programmed. Tap Shi to access
alphabec characters.
Sensor Types (Zone) RF Wired
(08) 24-Hour Auxiliary Alarm* Y Y
(09) 24-Hour Fire Y N
(10) Interior with Delay* Y Y
(14) 24-Hour Carbon Monoxide Y N
(16) 24-Hour Fire Verification Y N
(23) No Response Type* Y Y
(24) Silent Burglary Y Y
Sensor Type (Zone) Equipment Types
(04) Interior Follower (1) Motion
(2) Contact
(06) 24-Hour Silent Alarm (1) Contact
(11) Emergency
(07) 24-hour Audible Alarm (1) Contact
(11) Emergency
(08) 24-Hour Auxiliary (1) Contact
(6) Freeze
(8) Water
(10) Temperature
(11) Emergency
(10) Interior with Delay (1) Motion
(2) Contact
(23) No Response Type (1) Contact
(2) Motion
Installer Programming