Control Panel Programming
Q45: Lock Default Programming (0-2)
DEFAULT: (0) Default All
The Control Panel may be able to be hard reset (or so
reset from the Installer Toolbox) to its factory default values
depending on the value entered for this programming queson.
The Control Panel is hard reset by pressing and holding the
and
buons while applying power to the Control Panel.
The default lockout feature is provided to prevent takeovers.
Three opons are available: allow default of all opons, allow
default of some but not all opons, not allow default of any
opons.
• The default seng of (0) Default All allows reseng the
Control Panel to all its factory defaults.
• To allow reseng the Control Panel to all its factory
defaults except the Central Staon phone number, Central
Staon account number, lock installer programming,
download ID, and default lockout elds, select (1) Default
All Except CSID, Account/ Phone, Lockouts.
• To deny hard and so reseng of the Control Panel, select
(2) Default None.
If opon 1 or 2 is selected, the opon takes eect aer the
system runs for 48 hours. This allows the installer to go back
and make changes if required.
Q46: Trouble Doesn’t Sound at Night (0-1)
DEFAULT: (1) Enabled
NOTE: For UL 985: Household Fire Warning System Units
installaons, this seng must be set to (0) Disabled
The Control Panel will sound trouble beeps caused by AC loss,
system low baery, sensor low baery or RF supervision, failure
to communicate, Control Panel tamper while disarmed, and cell
radio faults.
To prevent annoying the subscriber, the system can be set to
suppress trouble beeps from sounding from 10
PM to 9 AM. The
trouble alerts are sll displayed and immediately reported to
the Central Staon, and can be acknowledged, but they won’t
sound beeps unl aer 9
AM.
If the trouble condion(s) self-clear or are acknowledged
before 9
AM, no trouble beeps sound aer 9 AM (the condions
are sll recorded in the event log).
• The default seng (1) Enabled suppresses trouble beeps
from 10
PM to 9 AM.
• To allow trouble beeps at any me, select (0) Disabled.
Q47: Trouble Resound After Hold Off (0-7)
DEFAULT: (0) Disabled
Fire and CO sensors are required to re-sound trouble beeps
every four hours unl the trouble is resolved, even if the
trouble is acknowledged at the Control Panel. The Control
Panel can be set to delay re-sounding these types of trouble
beeps for 1-7 days.
NOTE: This feature is not allowed in UL 985 installaons. The
seng must be (0) Disabled in this grade of installaon.
• The default seng (0) Disabled allows trouble beeps for
CO and re sensors to re-sound every four (4) hours aer
being acknowledged
• To delay re-sounding trouble beeps for CO and Fire
sensors, select (1-7) days
Q49: Programming Mode Entry Reports to
CS (0-1)
DEFAULT: (0) Disabled
A report can be sent to the Central Staon any me installer
programming mode is entered and exited.
• The default seng (0) Disabled prevents reporng
programming mode entry and exit.
• To report programming mode entry and exit, select (1)
Enabled.
NOTE: This report can only be sent through the telephone dialer.
It is not supported through the LTE (Cellular) Radio Module.
Q50: Trouble Reports to CS (0-1)
DEFAULT: (1) Enabled
Trouble reports can be sent to the Central Staon when any
sensor trouble condion occurs.
• The default seng (1) Enabled allows reporng sensor
trouble condions.
• To not report sensor trouble condions, select (0) Disabled.
NOTE: This seng does not aect trouble reports caused
by Control Panel condions, only trouble reports caused by
sensors.
Q51: Manual Bypass Reports to CS (0-1)
DEFAULT: (0) Disabled
Manual bypass reports can be sent to the Central Staon when
any sensor has been manually bypassed by the user.
• The default seng (0) Disabled prevents sending manual
bypass reports.
• To allow sending manual bypass reports, select (1) Enabled.
Q52: AC Loss Reports to CS (0-1)
DEFAULT: (1) Enabled
AC power loss reports can be sent to the Central Staon if the
Control Panel loses AC power.
• The default seng (1) Enabled allows AC power loss
reports.
• To turn o AC power loss reports, select (0) Disabled.
NOTE: The AC power will have to be absent from the Control
Panel for the me set by programming queson Q38 before the
AC power loss trouble alert
is displayed (the default is 10
minutes). If programming queson Q39 is enabled, the actual
AC power loss report will occur at a random me of up to four
hours aer the AC power loss trouble alert
is displayed.
NOTE: The Control Panel’s AC power icon displays the power
status immediately. A red “X” over the icon indicates no AC
power.
Q53: System Low Battery Reports to CS (0-1)
DEFAULT: (1) Enabled
Low baery reports can be sent to the Central Staon if the
Control Panel’s baery tests low.
• The default (1) Enabled allows Control Panel low baery
reports.
• To turn o Control Panel low baery reports, select (0)
Disabled.