GC2e Wireless Security System | Installation and Programming Guide
©2020 Nortek Security & Control LLC. All rights reserved. 54 2GIG is a registered trademark of Nortek Security & Control LLC.
Control Panel Programming
Q54: RF Low Battery Reports to CS (0-1)
DEFAULT: (1) Enabled
Sensor low baery reports can be sent to the Central Staon if a
sensor baery tests low and sends a low baery transmission to
the Control Panel.
The default seng is (1) Enabled and allows the system to
send low baery reports for sensors.
To turn this feature OFF, select (0) Disabled.
Q55: Opening Reports to CS (0-1)
DEFAULT: (0) Disabled
Opening reports can be sent to the Central Staon each me the
system is disarmed. The user or key fob number is indicated in
the opening report.
The default seng (0) Disabled prevents opening reports.
To allow opening reports, select (1) Enabled.
Q56: Closing Reports to CS (0-1)
DEFAULT: (0) Disabled
Closing reports can be sent to the Central Staon each me the
system is armed. The user or key fob number is indicated in the
closing report. If Quick Arming is enabled, User #0 is indicated for
the closing report.
The default seng (0) Disabled prevents closing reports.
To allow closing reports, select (1) Enabled.
Q57: Alarm Restore Reports to CS (0-1)
DEFAULT: (0) Disabled
Alarm restore reports can be sent to the Central Staon aer
an alarm when either the bell meout has been reached or the
system is disarmed. If alarm restores are enabled and swinger
shutdown is set to two, a restore will be reported if the sensor is
closed (normal st ate) at bell cuto or becomes closed aer bell
cuto. If swinger shutdown is set to one, a restore will only be
sent if the sensor is closed at the me of disarm. Restores are not
sent if a sensor is in swinger shutdown unl the me of disarm
and the sensor is closed.
The default seng (0) Disabled prevents alarm restore
reports.
To allow alarm restore reports, select (1) Enabled.
Q58: Trouble Restore Reports to CS (0-1)
DEFAULT: (1) Enabled
Trouble restore reports can be sent to the Central Staon when
any sensor trouble condion clears.
The default seng (1) Enabled allows the system to send
reports when trouble condions are restored.
To turn this feature OFF, select (0) Disabled.
Q59: Bypass Restore Reports to CS (0-1)
DEFAULT: (0) Disabled
Bypass restore reports can be sent to the Central Staon when
any sensor that was force bypassed or manually bypassed gets
restored.
The default seng (0) Disabled prevents bypass restore
reports.
To allow bypass restore reports, select enabled (1) Enabled.
Q60: AC Restore Reports to CS (0-1)
DEFAULT: (1) Enabled
AC power restore reports can be sent to the Central Staon when
the Control Panel regains AC power aer an AC power loss.
The default seng (1) Enabled allows AC power restore
reports.
To turn o AC power restore reports, select (0) Disabled.
NOTE: The AC power will have to be restored to the Control
Panel for one minute before the AC power loss trouble alert
automacally clears. If programming queson Q39 is
enabled, the actual AC power restore report will occur at
a random me of up to four hours aer the AC power loss
trouble alert
has cleared.
NOTE: The Control Panel’s AC power icon displays the power
status. A red “X” over the icon indicates no AC power.
Q61: System Low Battery Restore Reports
to CS (0-1)
DEFAULT: (1) Enabled
When a low baery condion is restored on the Control Panel,
the system can send a restore report to the Central Staon.
The default seng (1) Enabled allows the system to send
reports when low baery condions are restored.
To turn this feature OFF, select (0) Disabled.
Q62: RF Low Battery Restore Reports to
CS (0-1)
DEFAULT: (1) Enabled
Sensor low baery restore reports can be sent to the Central
Staon if a sensor baery had tested low and is now OK.
The default seng (1) Enabled allows sensor low baery
restore reports.
To turn o sensor low baery restore reports, select (0)
Disabled.
Q64: Smart Test Reports
DEFAULT: (0) Disabled
Smart test reports are a way to reduce Central Staon trac.
If smart test reports are enabled and regular periodic test
reports are enabled, any non-test report to the Central Staon
(alarm, restore, trouble, etc.) during the normal operaon of
the system will reset the periodic test report mer . Periodic
test reports would only be sent if the Control Panel has not
reported in any way to the Central Staon.
The default seng (0) Disabled prevents smart test reports.
To allow smart test reports, select (1) Enabled.
Q65: RF Jam Causes Trouble (0-1)
DEFAULT: (0) Disabled
The system can monitor the Control Panel’s sensor receiver
and detect whether a transmier is stuck on the air causing
jamming. When jam detect is enabled, the Control Panel will
indicate a trouble condion if RF jamming is detected.
NOTE: This programming queson only funcons if trouble
reports are enabled with programming queson Q50.
The default seng (0) Disabled turns RF jam detecon
OFF.
To turn on RF jam detecon, select (1) Enabled.