Control Panel Programming
Q76: Force Bypass Reports (0-1)
DEFAULT: (0) Disabled
The system can report which sensors have been force bypassed by
the user when the system is armed. Forced bypassed sensors are
always recorded in the event log, regardless of the seng of this
programming queson.
• The default seng (0) Disabled prevents reporng forced
bypassed sensors.
• To report forced bypassed sensors, select (1) Enabled.
Q77: Event Log (0-3)
DEFAULT: (3) All Events
To control the amount of event log entries, the events that get
recorded into the system’s event log can be selected by type. This
seng lters the events that populate the event log.
• The default seng (3) All Events records all events in the
event log.
• To choose dierent opons, select one of these lters:
Q82: Z-Wave Door Locks Feature (0-1)
DEFAULT: (1) Enabled
Display of the Home Service’s Door Locks buon can be enabled or
disabled. This programming queson only funcons if the Z-Wave
feature enable queson Q79: Z‐ Wave Feature is set to (2) or (3).
• The default seng (1) Enabled shows the Door Locks buon.
• To hide the Door Locks buon, select (0) Disabled.
Q83: Select Temperature Display Units (0-1)
DEFAULT: (0) Degrees Fahrenheit
The Home Service’s Z-Wave thermostat display screens can show
the temperature in degrees Fahrenheit or degrees Celsius.
NOTE: This programming queson only funcons if Q79: Z- Wave
Feature is set to (2) or (3) and Q81: Z-Wave Thermostats Feature
is set to (1) Enabled.
• The default seng is (0) Degrees Fahrenheit.
• To change the seng, select (1) Celsius.
NOTE: The seng you select here also changes the display units
shown on the weather forecast on the Control Panel’s Home screen.
Q84: Services Require Master Code (0 to 1)
DEFAULT: (0) Disabled
The Services buon can be congured to require the use of the
master user code to access Services.
• The default seng (0) Disabled overrides the requirement to
enter a master user code to access the Services menu.
To require the use of the master user code to access the Services
menu, select (1) Enabled.
When enabled then the master user code is required to access
the Services and the Z-Wave device conguraons. This keeps
unauthorized users from being able to change Z- Wave sengs,
such as temperature, lights and locks.
Q85: Master User Access to Z-Wave Toolbox
(0-1)
DEFAULT: (0) Disabled
The Z-Wave Toolbox menu can be set to require the use of the
master user code or the installer code. By default, the installer
code is required for users to access the Z-Wave Toolbox.
• The default seng (0) Disabled requires users to enter the
installer code to access the Z-Wave Toolbox menu and all of
its features, including the Advanced Toolbox.
• To require the use of the master user code or the installer
code to access the Z-Wave Toolbox menu, select (1) Enabled.
NOTE: When (1) Enabled, the Installer code will sll be required
to access the Advanced Toolbox menu. This prevents end users
from adding or removing Z-Wave devices.
Q86: Disable Siren After Two-Way Audio (0-1)
DEFAULT: (0) Disabled
This seng enhances system operaon in personal emergency
applicaons and also provides the dealer with the opon of the
siren sounding unl the bell cut o or to the end of a two-way-
voice session.
• The default seng (0) Disabled will cause the siren to resume
aer two-way audio (if the bell cut o mer has not expired).
• (1) Enabled will cause the siren to shut o aer a two-way
audio session.
Q80: Z-Wave Switches Feature (0 to 1)
DEFAULT: (1) Enabled
Display of the Home Service’s Switches buon can be enabled or
disabled.
NOTE: This programming queson only funcons if Q79: Z- Wave
Feature is set to (2) or (3).
• The default seng (1) Enabled shows the Switches buon.
• To hide the Switches buon, select (0) Disabled.
Q81: Z-Wave Thermostats Feature (0 to 1)
DEFAULT: (1) Enabled
Show or hide the Home Service’s Thermostats buon on the
Control Panel.
NOTE: This programming queson only funcons if Q79: Z- Wave
Feature is set to (2) or (3).
• The default seng (1) Enabled shows the Thermostats buon.
• To hide the Thermostats buon, select (0) Disabled.
Event Log Filters
(0) Disabled (no events logged)
(1) All Events Except Open, Closing, and Bypass
(2) All Events Except Open and Closing
(3) All Events
Q79: Z-Wave Feature (0-3)
DEFAULT: (3) (3) Enabled on Panel; Rules Disabled, Remote Access Enabled
The Z-Wave home services feature can be enabled or disabled with
various remote control access opons.
• The default seng (3) Enabled on Panel; Rules Disabled,
Remote Access Enabled displays the Services buon, but will
show a message that the feature is currently disabled and the
user should call the installer.
• To hide the Services buon, select (0) Disabled and Hidden.
• To show the Services buon but disable it from use, select (1)
Disabled but Visible.
• To show the Services buon and disable o- site remote
control, select (2) Enabled on Panel, Remote Access Disabled.