GC2e Wireless Security System | Installation and Programming Guide
©2020 Nortek Security & Control LLC. All rights reserved. 58 2GIG is a registered trademark of Nortek Security & Control LLC.
Control Panel Programming
Q: Select Used (0 to 1)
DEFAULT: (0) Disabled
NOTE: Typically, you will skip this queson unless addional
programming is required.
It is re commended that you always select the default seng (0)
Disabled. If you choose (1) Enabled, you will be prompted to enter
the port value.
Q: Enter Port Value (0 to 65535)
DEFAULT: (0) Disabled
NOTE: Typically, you will skip this queson unless addional
programming is required.
It is re commended that you always select the default seng (0)
Disabled. If you select (1) Enabled in Q: Select Used (0 to 1), use the
numeric keypad to enter the port value.
NOTE: The port value is the port number for Transmission Control
Protocol (TCP) communicaon. Port numbers can range from 0 to
65535.
Q: Enter Port Forward IP Address
DEFAULT: 000.000.000.000
Typically, you will simply accept the default IP Address value that
appears.
Q93: Enter Broadband Network Failure Time
(1-255)
DEFAULT: 30 Minutes
NOTE: The Go!Bridge IP Communicator must be installed to use this
funcon.
This opon sets the amount of me required for triggering a
trouble condion if the system detects that the broadband network
has lost its connecon. Aer the connecon has been restored, the
trouble condion clears.
The default failure detecon seng is 30 minutes.
To choose a dierent failure detecon me, enter the number
of minutes between 1‐255.
Q94: Select Broadband Network Failure
Causes Trouble (0 to 1)
DEFAULT: (1) Enabled
NOTE: The Go!Bridge IP Communicator must be installed to use this
funcon.
This opon species whether or not the Control Panel will sound
and display a trouble alert if the Go!Bridge IP Communicator loses
its broadband connecon. The trouble alert can be silenced by the
user at the Control Panel (broadband trouble is logged regardless
of this seng). When the broadband connecon is re stored, the
trouble indicaons automacally clear.
The default seng (1) Enabled allows Go!Bridge network
failure trouble indicaons.
To turn o Go!Bridge trouble indicaons, select (0) Disabled.
Q95: Select Broadband Network Failure
Reports (0 to 1)
DEFAULT: (1) Enabled
NOTE: The Go!Bridge IP Communicator must be installed to use
this funcon.
If the Go! Bridge IP Communicator loses its broadband
connecon, the Control Panel can report the fault.
The default seng is (1) Enabled which turns broadband
network failure reporng ON.
To turn broadband network failure reporng OFF, select (0)
Disabled.
Q96: Select Send Report 3 Times on Panel
Tamper (0 to 1)
DEFAULT: (1) Enabled
NOTE: For compliance with UL 1610, this queson must be set to
(1) disabled.
This opon congures the system to transmit three (3) reports
to the Central Staon when the system detects that the panel’s
backplate is in a tamper condion.
(1) Enabled. The system transmits three (3) reports to the
Central Staon.
(0) Disabled. The system only transmits a single report to
the Central Staon.
Q97: Select Sound on Normal Closing
Acknowledgment (0 to 1)
DEFAULT: (1) Enabled
Congures the system to emit a sound when the system
acknowledges that an open sensor has closed (i.e., returned to
its normal state).
(1) Enabled. The system emits a sound on sensor closing.
(0) Disabled. No sound is emied on sensor closing.
NOTE: For compliance with UL 1610, this queson must be set
to (1) Enabled. In addion, Q91 must be set to (1) Radio Modem
Supplier 1.
Q98: Select enable 6-digit PIN (0-1)
DEFAULT: (0) Disabled
Congures the system to use 6-digit pin codes.
(0) disabled (4-digit pin codes)
(1) enabled (6-digit pin codes)
Note: Changing Q98 to 1 changes the length of all Pin Codes
(User, Duress, Master, and Installer Codes)
Note: If changing from 4 to 6-digit pin codes, all exisng codes
will be appended with “11”. The default 6-digit Installer pin code
is 156111 and Master 111111.
NOTE: When changing from 6 to 4-digit pin codes all pin codes
will be truncated, removing the last 2 digits. If this acon
causes conicts, the system will prompt to resolve the conicts.
Conicts can be resolved by defaulng the user codes or
changing the exisng pin codes so that no rst four digits of the
pin codes are the same.