Control Panel Programming
Q: Select Used (0 to 1)
DEFAULT: (0) Disabled
NOTE: Typically, you will skip this queson unless addional
programming is required.
It is re commended that you always select the default seng (0)
Disabled. If you choose (1) Enabled, you will be prompted to enter
the port value.
Q: Enter Port Value (0 to 65535)
DEFAULT: (0) Disabled
NOTE: Typically, you will skip this queson unless addional
programming is required.
It is re commended that you always select the default seng (0)
Disabled. If you select (1) Enabled in Q: Select Used (0 to 1), use the
numeric keypad to enter the port value.
NOTE: The port value is the port number for Transmission Control
Protocol (TCP) communicaon. Port numbers can range from 0 to
65535.
Q: Enter Port Forward IP Address
DEFAULT: 000.000.000.000
Typically, you will simply accept the default IP Address value that
appears.
Q93: Enter Broadband Network Failure Time
(1-255)
DEFAULT: 30 Minutes
NOTE: The Go!Bridge IP Communicator must be installed to use this
funcon.
This opon sets the amount of me required for triggering a
trouble condion if the system detects that the broadband network
has lost its connecon. Aer the connecon has been restored, the
trouble condion clears.
• The default failure detecon seng is 30 minutes.
• To choose a dierent failure detecon me, enter the number
of minutes between 1‐255.
Q94: Select Broadband Network Failure
Causes Trouble (0 to 1)
DEFAULT: (1) Enabled
NOTE: The Go!Bridge IP Communicator must be installed to use this
funcon.
This opon species whether or not the Control Panel will sound
and display a trouble alert if the Go!Bridge IP Communicator loses
its broadband connecon. The trouble alert can be silenced by the
user at the Control Panel (broadband trouble is logged regardless
of this seng). When the broadband connecon is re stored, the
trouble indicaons automacally clear.
• The default seng (1) Enabled allows Go!Bridge network
failure trouble indicaons.
• To turn o Go!Bridge trouble indicaons, select (0) Disabled.
Q95: Select Broadband Network Failure
Reports (0 to 1)
DEFAULT: (1) Enabled
NOTE: The Go!Bridge IP Communicator must be installed to use
this funcon.
If the Go! Bridge IP Communicator loses its broadband
connecon, the Control Panel can report the fault.
• The default seng is (1) Enabled which turns broadband
network failure reporng ON.
• To turn broadband network failure reporng OFF, select (0)
Disabled.
Q96: Select Send Report 3 Times on Panel
Tamper (0 to 1)
DEFAULT: (1) Enabled
NOTE: For compliance with UL 1610, this queson must be set to
(1) disabled.
This opon congures the system to transmit three (3) reports
to the Central Staon when the system detects that the panel’s
backplate is in a tamper condion.
• (1) Enabled. The system transmits three (3) reports to the
Central Staon.
• (0) Disabled. The system only transmits a single report to
the Central Staon.
Q97: Select Sound on Normal Closing
Acknowledgment (0 to 1)
DEFAULT: (1) Enabled
Congures the system to emit a sound when the system
acknowledges that an open sensor has closed (i.e., returned to
its normal state).
• (1) Enabled. The system emits a sound on sensor closing.
• (0) Disabled. No sound is emied on sensor closing.
NOTE: For compliance with UL 1610, this queson must be set
to (1) Enabled. In addion, Q91 must be set to (1) Radio Modem
Supplier 1.
Q98: Select enable 6-digit PIN (0-1)
DEFAULT: (0) Disabled
Congures the system to use 6-digit pin codes.
(0) disabled (4-digit pin codes)
(1) enabled (6-digit pin codes)
Note: Changing Q98 to 1 changes the length of all Pin Codes
(User, Duress, Master, and Installer Codes)
Note: If changing from 4 to 6-digit pin codes, all exisng codes
will be appended with “11”. The default 6-digit Installer pin code
is 156111 and Master 111111.
NOTE: When changing from 6 to 4-digit pin codes all pin codes
will be truncated, removing the last 2 digits. If this acon
causes conicts, the system will prompt to resolve the conicts.
Conicts can be resolved by defaulng the user codes or
changing the exisng pin codes so that no rst four digits of the
pin codes are the same.