GC2e Wireless Security System | Installation and Programming Guide
©2020 Nortek Security & Control LLC. All rights reserved. 62 2GIG is a registered trademark of Nortek Security & Control LLC.
Radio Status Test
If the LTE (Cellular) Radio Module is installed in the Control
Panel, use the Radio Status screen to view signal strength,
serial number, registraon status, and other informaon for
the cellular connecon. The is a helpful tool to use when
troubleshoong the installaon.
Cell Phone Test
To perform a cell phone test:
1 At the Installer Toolbox screen, tap Radio Status.
Figure 61
Installer Toolbox: Radio Status
2. When the System Test: Sensors screen appears, you can
tap the ↓ and ↑ arrows to scroll through the sensor list.
Figure 58
System Test: Sensors Screen
3. Walk to the rst sensor in the list, and then acvate that
sensor to test it.
When the panel receives the signal, it emits (3) beeps
and then GREEN or RED bars show the signal strength.
The greater the number of bars, the higher the strength.
If the signal is sucient, a check mark appears. If
insucient, an “x” appears.
Figure 59
System Test: Sensors Screen/Signal Strength
2. At the Radio Status screen, tap Cell Phone Test.
Figure 62
Radio Status Screen
4. Repeat the test for each sensor in the list. If you are
tesng a sensor with mulple loops, (for example, a
Smoke/Heat/Freeze alarm), wait 15 seconds between
each loop’s test.
NOTE: If a sensor is not detected, no signal will register. Tap
OK. Then at the Sensors Test Failed screen, tap OK.
5. At the System Test: Console screen, tap each buon to
test the panel’s LED buons and audio.
Figure 60
System Test: Console
The Cell Phone Test screen appears to reveal status
messages and test results
Figure 63
Cell Phone Test Screen
3. When the results appear, tap the ↓ and ↑ arrows to
review the messages:
• RED text indicates the tested signal strength is zero,
too low, or that the LTE (Cellular) Radio Module is
unregistered.
• ORANGE text indicates the connecon is idle and the
LTE (Cellular) Radio Module is registered.
• GREEN text indicates good signal strength and that the
LTE (Cellular) Radio Module is registered.
4. When the results are successful, tap OK to return to the
Toolbox (3 of 3) screen.
6. When the console tests are complete, tap OK. When the
test is successfully completed, tap OK to exit Walk Test
mode. The system sends a “Stop Test” report to the Central
Staon.
Installer Testing