Control Panel Programming
Copyright ยฉ 2016 Nortek Security & Control 53
Q11: CS #1 Phone Number (0-25 Digits)
DEFAULT:๎No๎Default
Enter๎the๎telephone๎number๎for๎the๎Central๎Station๎#1.๎You๎
can๎enter๎up๎to๎25๎digits.
โขEnter๎the๎Central๎Station๎#1๎telephone๎number.
โขTap๎Shi
ft๎to๎access๎the๎pound๎(#)๎and๎star๎(*)๎
symbols.๎The๎P๎button๎adds๎a๎three๎(3)โsecond๎
pause๎to๎the๎dialing.
NOTE: If๎a๎se
cond๎Central๎Station๎telephone๎number๎is๎
programmed๎with๎question๎Q41:๎CS๎#2๎Account๎
Number,๎the๎Control๎Panel๎alternates๎between๎the๎two๎
Central๎Station๎telephone๎numbers.๎After๎two๎failed๎
telephone๎dialing๎attempts,๎the๎Control๎Panel๎attempts๎
to๎connect๎using๎the๎GSM๎(Cellular)๎Radio๎Module๎if๎it๎is๎
installed.๎If๎the๎GSM๎(
Cellular)๎Radio๎Module๎is๎not๎
installed,๎the๎Control๎Panel๎will๎make๎eight๎(8)๎dialing๎
attempts.
Q12: CS #1 Account Number (4 Digits)
DEFAULT:๎No๎Default
Enter๎the๎account๎number๎for๎Central๎Station๎#1.๎This๎
number๎is๎always๎four๎(4)๎digits๎and๎can๎include๎some๎alpha๎
characters.
โขEnter๎th
e๎four๎(4)๎digit๎for๎the๎Central๎Station๎#1๎
account๎number.
โขTap๎Shi
ft๎to๎gain๎access๎to๎these๎characters:๎B,๎C,๎D,๎E,๎
and๎F.
Q13: 2-Way Voice (0-2)
DEFAULT:๎(1)๎Stay๎On๎Line
The๎Control๎Panel๎supports๎two๎(2)โwa y๎voice๎
communications๎between๎the๎subscriber๎and๎the๎Central๎
Station๎operator๎over๎the๎telephone๎line๎or๎the๎GSM๎
(Cellular)๎Radio๎Module๎(if๎installed)๎after๎an๎alarm๎has๎
been๎reported.
โขThe๎(1)๎St
ay๎On๎Line๎allows๎two๎(2)โway๎audio๎over๎the๎
telephone๎line๎or๎cell๎radio.
โข Selecting๎(2)๎St
ay๎On๎Line,๎Including๎Fire๎and๎CO๎Alarms๎
allows๎2โway๎audio๎over๎the๎telephone๎line๎or๎cell๎radio๎
during๎fire๎and๎CO๎alarms.
โขTo๎turn๎of
f๎the๎two๎(2)โwa y๎audio๎feature๎OFF,๎select๎(0)๎
Disabled.
When๎the๎Con
trol๎Panel๎connects๎with๎the๎operator,๎it๎will๎
beep๎once๎per๎second๎(every๎6๎seconds๎with๎a๎cell๎radio๎
connection).๎The๎beep๎alternates๎between๎two๎tones๎and๎
indicates๎the๎Control๎Panel๎is๎waiting๎for๎a๎session๎
command.๎If๎the๎operator๎fails๎to๎issue๎a๎command๎within๎
one๎(1)๎minute๎(or๎thr
ee๎(3)๎minutes๎if๎using๎the๎cell๎radio๎
connection),๎the๎call๎is๎terminated.๎Once๎the๎operator๎
presses๎a๎command๎option,๎the๎beeps๎will๎stop๎and๎a๎five๎
(5)โminute๎audio๎session๎will๎start๎(or๎three๎(3)โminute๎
audio๎session๎if๎using๎the๎cell๎radio๎connection).
When๎two๎(2)โway๎voice๎co
mmunications๎have๎been๎
established,๎the๎Central๎Station๎operator๎can๎use๎the๎
following๎telephone๎keys๎to๎control๎the๎communications.๎
Each๎time๎the๎operator๎uses๎a๎command๎key,๎the๎session๎is๎
extended๎for๎five๎additional๎minutes๎(three๎minutes๎with๎a๎
cell๎radio๎connection).๎During๎the๎last๎minute๎of๎
communications,๎the๎system๎beeps๎two๎(2)๎time
s๎every๎15๎
seconds๎to๎indicate๎that๎time๎is๎running๎out.
โขTap๎1๎to๎en
able๎Talk๎mode๎one๎(1)โway๎
communication๎from๎the๎Central๎Station๎to๎the๎
premises๎and๎allows๎the๎operator๎to๎talk.
โขTap๎2๎to๎en
able๎VOX๎mode๎two๎(2)โway๎
communications๎from๎the๎Central๎Station๎to๎the๎
premises.
โขTap๎3๎to๎en
able๎Listen๎mode๎one๎(1)โway๎
communication๎from๎the๎premises๎to๎the๎Central๎
Station.
โขTap๎7๎to๎ex
tend๎the๎session๎five๎(5)๎minutes๎without๎
changing๎the๎mode๎of๎operation.
โขTap๎9๎to๎en
d๎the๎audio๎session๎an๎terminate๎the๎
call.
Q14: Silent Panic/Burglary Listen Only
DEFAULT:๎(1)๎Enabled
The๎Control๎Panel๎supports๎audio๎listenโin๎of๎the๎subscriber๎
premises๎from๎the๎Central๎Station๎over๎the๎telephone๎line๎
after๎a๎silent๎panic๎(police๎emergency),๎silent๎burglary,๎or๎
duress๎alarm๎has๎been๎reported.
โขThe๎de
fault๎setting๎(1)๎Enabled๎allows๎the๎Central๎
Station๎to๎use๎listenโin๎over๎audio๎after๎a๎silent๎panic,๎
silent๎burglary,๎or๎duress๎alarm.
โขThis๎opt
ion๎is๎permanently๎set๎and๎cannot๎be๎disabled.
Q15: Dialing Type (0-1)
DEFAULT:๎(0)๎Touch๎To ne
The๎digital๎communicator๎uses๎tones๎or๎pulses.
โขThe๎de
fault๎set ting๎(0)๎Touch๎Tone๎is๎for๎DualโTone๎
MultiโFrequency๎(DTMF)๎dialing.
โขFor๎ro
tary๎dialing,๎select๎(1)๎Pulse.
Q16: Police Emergency Key (0-2)
DEFAULT:๎(1)๎Audible
The๎Control๎Panelโ s๎panic๎emergency๎button๎action๎can๎be๎
programmed.๎The๎panic๎emergency๎button๎is๎displayed๎by๎
pressing๎the๎๎button.
โขThe๎de
fault๎(1)๎Audible๎allows๎the๎panic๎emergency๎
button๎to๎sound๎an๎audible๎alarm.
โขFor๎si
lent๎activation,๎select๎(2)๎Silent๎Panic.
โขTo๎dis
able๎and๎not๎display๎the๎panic๎emergency๎
button,๎select๎(0)๎Disabled.
NOTE: Set
ting๎this๎programming๎question๎for๎(2)๎Silent๎
Panic๎makes๎the๎Police๎button๎on๎all๎RF๎keypads๎silent๎
also.
Q17: Fire Emergency Key (0-1)
DEFAULT:๎(1)๎Audible
The๎Control๎Panelโ s๎fire๎emergency๎button๎can๎be๎enabled๎
or๎disabled.๎The๎fire๎emergency๎button๎is๎displayed๎by๎
pressing๎the๎Control๎Panelโs๎๎button.
โขThe๎de
fault๎set ting๎(1)๎Audible๎allows๎the๎fire๎
emergency๎button๎to๎sound๎an๎audible๎alarm.