Control Panel Programming
Copyright © 2016 Nortek Security & Control 55
Whenautostayisenabledandthesystemisarmedinthe
Awaymode,ifanexit/entrysensorisnotviolatedduring
theExitDelay,thesystemwillarmintheStaymode.
•Thedefaultsettingis(1)Enabledwhichturnsthe
auto‐stayfeatureON.
•Toturnthisfeatureoff,select(0)Disabled.
NOTE: Ifthesy
stemisremotelyarmedinAwaymodeusing
akeyfob,telephone,mobileapp,orcomputer,the
auto‐stayfeaturewillnotswitchthesystemtoStay
mode.
Q27: Exit Delay Restart (0-1)
DEFAULT:(1)Enabled
ThisfeaturemustbeenabledforANSI/SIACP‐01
compliance.
WhenExitDelayrestartisenabled,re‐enteringthe
premisesthroughanexit/entrydoorduringtheExitDelay
willrestarttheExitDelay.TherestartoftheExitDelaywill
onlyoccuronetime;furtherviolationsofanex
it/entry
sensorwillnotextendtheExitDelay.
•Thede
faultsetting(1)Enabledturnsthisfeature
ON.
•Toturnthisfe
atureOFF,select(0)Disabled.
Q28: Quick Exit (0-1)
DEFAULT:(1)Enabled
ThequickexitfeatureallowstheusertostarttheExitDelay
whilethesystemisarmed.Whenthisfeatureisenabled,a
QuickExitbuttonappearsontheSecurityscreen.TapQuick
Exitwhilethesystemisarmedwhentheuserwantsto
leavethroughanexit/entrydoor.Af
tertheExitDelay
expires,thesystemwillreturntobeingarmedinthemode
itwasinbefore(eitherStayorAwaymode).
•Thede
faultsetting(1)Enabledturnsthisfeature
ON.
•ToturnthisfeatureOFF,select(0)Disabled.
Q29: Periodic Test, in Days (0-255)
DEFAULT:30Days
Recurringtestreportscanbeautomaticallysenttothe
CentralStationataspecifiednumberofdays.
•Thede
faultsettingis30.Thissendsanautomatic
testreporttotheCentralStationevery30days.
•Toch
angethenumberofdays,enteravalue
betweenone(1)to255days.
•Todisab
lethisfeature,select(0)Disabled.
Q31: Cancel Time, in Minutes (5-255)
DEFAULT:5minutes
TheminimumsettingforANSI/SIACP‐01complianceis5
minutes.Thenumberofminutescanbeincreasedwithout
affectingANSI/SIACP‐01compliance.
AcancelreportwillbesenttotheCentralStationafteran
alarm,ifthesystemisdisarmedwithintheprogrammed
time.
•Thede
faultsettingforthecancellationtimeisfive(5)
minutes.
•Toextendthistimeinterval,enteravaluebetweensix
(6)to254minutes.
•Toalw
ayssendacancelreportwhenthesystemis
disarmedafteranalarm,enter255.
NOTE: SeeQ32:Can
celDisplayforinformationon
displayingwhenacancelreportissent.
Q32: Cancel Display (0-1)
DEFAULT:(1)Enabled
ThisfeaturemustbeenabledforANSI/SIACP‐01
compliance.
AcancelreportwillbesenttotheCentralStationafteran
alarm,ifthesystemisdisarmedwithintheprogrammed
time.TheControlPanelcanalsodisplaythatacancelreport
wassent.
•Thede
faultset ting(1)Enabledenablesthecancel
displayfeature.
•Totu
rnoffthecanceldisplayfeature,select(0)
Disabled.
NOTE: SeeQ31:Canc
elTime,inMinutesforinformationon
settingthecancelreporttriggertime.
Q33: Cross Sensor 47-48 (0-1)
DEFAULT:(0)Disabled
TheControlPanelcanbeprogrammedsosensors47and48
mustbothbeviolatedduringasettimetotriggeranalarm.
Thisiscalled“crosssensor”verification.Whenenabled,if
onlyonesensor(47or48)isviolated,thealarmwillnot
trigger,butatroublereportwillbese
ntforthesensorthat
triggered.
NOTE: COan
dFirezonecannotbeusedforcrosssensors.
•Thede
faultset ting(0)Disabledturnsthecross
sensorfeatureOFF.
•Totu
rnthecrosssensorfeatureON,select(1)
Enabled.
NOTE: SeeQ34:Cr
ossSensorTimeout,inSecondsfor
informationonsettingthecrosssensortimeout.
Q34: Cross Sensor Timeout, in Seconds
(10-120)
DEFAULT:10Seconds
Thecrosssensortimeoutisthemaximumperiodoftime
allowedbetweenviolationofsensors47and48thatwill
triggeranalarm.Ifbothsensorsareviolatedwithinthis
timeperiod,analarmwillbetriggered.Ifbothsensorsare
notviolatedwithinthistimeperiod,analarmwi
llnotbe
triggered.
NOTE: Cr
osssensorverificationmustbeenabledwith
Q33:CrossSe
nsor47‐48forthisfeaturetofunction.
•Thede
faultset tingforthecrosssensortimeoutis
10seconds.