Go!ControlWirelessSecuritySystem|InstallationandProgrammingGuide
62Copyright©2016NortekSecurity&Control
•Thedefaultsetting(1)EnabledshowstheSwitches
button.
•Tohideth
eSwitchesbutton,select(0)Disabled.
Q81: Z-Wave Thermostats Feature (0 to
1)
DEFAULT:(1)Enabled
ShoworhidetheHomeService’sThermostatsbuttonon
theControlPanel.
NOTE: Thispr
ogrammingquestiononlyfunctionsifQ79:Z‐
WaveFeatureissetto(2)or(3).
•Thede
faultsetting(1)EnabledshowstheThermostats
button.
•Tohideth
eThermostatsbutton,select(0)Disabled.
Q82: Z-Wave Door Locks Feature (0-1)
DEFAULT:(1)Enabled
DisplayoftheHomeService’sDoorLocksbuttoncanbe
enabledordisabled.Thisprogrammingquestiononly
functionsiftheZ‐WavefeatureenablequestionQ79:Z‐
WaveFeatureissetto(2)or(3).
•Thede
faultsetting(1)EnabledshowstheDoorLocks
button.
•TohidetheDoorLocksbutton,select(0)Disabled.
Q83: Select Temperature Display Units
(0-1)
DEFAULT:(0)DegreesFahrenheit
TheHomeService’sZ‐Wavethermostatdisplayscreenscan
showthetemperatureindegreesFahrenheitordegrees
Celsius.
NOTE: Thispr
ogrammingquestiononlyfunctionsifQ79:Z‐
WaveFeatureissetto(2)or(3)andQ81:Z‐Wave
ThermostatsFeatureissetto(1)Enabled.
•Thede
faultsettingis(0)DegreesFahrenheit.
•Toch
angethesetting,select(1)Celsius.
NOTE: These
ttingyouselectherealsochangesthedisplay
unitsshownontheweatherforecastontheControl
Panel’ sHomescreen.
Q84: Services Require Master Code (0 to
1)
DEFAULT:(0)Disabled
TheServicesbuttoncanbeconfiguredtorequiretheuseof
themasterusercodetoaccessServices.
•Thede
faultsetting(0)Disabledoverridesthe
requirementtoenteramasterusercodetoaccessthe
Servicesmenu.
•Tore
quiretheuseofthemasterusercodetoaccessthe
Servicesmenu,select(1)Enabled.
Whenen
abledthenthemasterusercodeisrequiredto
accesstheServicesandtheZ‐Wavedeviceconfigurations.
ThiskeepsunauthorizedusersfrombeingabletochangeZ‐
Wavesettings,suchastemperature,lightsandlocks.
Q85: Master User Access to Z-Wave
Toolbox (0-1)
DEFAULT:(0)Disabled
TheZ‐WaveToolboxmenucanbesettorequiretheuseof
themasterusercodeortheinstallercode.Bydefault,the
installercodeisrequiredforuserstoaccesstheZ‐Wave
Toolbox.
•Thede
faultsetting(0)Disabledrequiresuserstoenter
theinstallercodetoaccesstheZ‐WaveToolboxmenu
andallofitsfeatures,includingtheAdvancedToolbox.
•Tore
quiretheuseofthemasterusercodeorthe
installercodetoaccesstheZ‐WaveToolboxmenu,
select(1)Enabled.
NOTE: Whe
n(1)Enabled,theInstallercodewillstillbe
requiredtoaccesstheAdvancedToolboxmenu.This
preventsendusersfromaddingorremovingZ‐Wave
devices.
Q86: Disable Siren After Two-Way Audio
(0-1)
DEFAULT:(0)Disabled
Thissettingenhancessystemoperationinpersonal
emergencyapplicationsandalsoprovidesthedealerwith
theoptionofthesirensoundinguntilthebellcutofforto
theendofatwo‐way‐voicesession.
•Thedefaultsetting(0)Disabledwillcausethesirento
resumeaftertwo‐wayaudio(ifthebellcutofftimerhas
notexpired).
• (1)E
nabledwillcausethesirentoshutoffafteratwo‐
wayaudiosession.
Q87: Keyfob/Remote Arming Mode on
System Not Ready (0-2)
DEFAULT:(0)AutoBypasswithZoneParticipationon
Restore
Thissettingcontrolshowthesystemwillreactwhenthere
areopensensorsandthesystemisarmedremotely.
•Thede
faultsetting(0)Disabledwillautomatically
bypassallsensorsthatareopenwhenthesystemis
armedremotely.Ifasensorrestoreswhilethesystemis
armed,thesensor’sbypasswillbe removed,andthe
sensorwillbereadytotriggeranalarm.
•Toau
tomaticallybypassallsensorsthatareopenwhen
thesystemisarmedremotely,andkeepallbypassesin
placeduringthearmingcycle,evenifasensorrestores,
select(1)Auto‐Bypass.
•Toprev
entarmingremotelywhenanysensorisopen,
select(2)ArmOnlyWhenReady.
Q88: Siren Mode (0-1)
DEFAULT:(0)SoundforBurglaryandFire/CO
ThissettingselectswhichalarmtypeswillactivateaZ‐Wave
sirenlinkedtothesystem.
Thedefaultsetting(0)SoundforBurglaryandFire/CO
causesaZ‐Wavesirentosoundduringbur glaryandFire/CO
alarms.
•Toha
veaZ‐Wavesirensoundonlyduringburglary
alarms,select(1)SoundforBurglaryOnly.