DC Inverter U-match Series Cassette Type Unit
25
Fig. 4.32
(3). If gap still exists between ceiling and decorative panel after tightening the
screws, readjust the height of the indoor unit (Fig. 4.33).
Fig. 4.33
(4). Wire the swing flap motor
and
lamps to the main body
according to the size of
Terminals and the connection
cord color as shown in
Fig.4.34.
Fig. 4.34
4.6.2 Installing the Panel
(1). Place the panel at the unit, and latch the hooks beside and opposite the
swing flap motor.
(2). Latch other two hooks.
(3). Tighten four hexagonal screws under the latches about 15mm (5/8inch).
(4). Adjust the panel along the direction indicated by the arrow as shown in Fig.