7
1) Connect to appropriate power supply; the voltage should comply with the rated voltage of
the products.
2) Heater must be grounded.
3) Wiring must be handled by a professional technician according to the circuit diagram.
4) NorthFlo VS units do not require a GFCI to function. If required by code, please respect
following guidelines.
i. Set GFCI according to the local code for wiring (current leakage ≤ 30mA).
ii. Some GFCI breakers may cause nuisance trips with variable speed products. Consult
a certified electrician, your retailer or Moov to confirm wiring. Product Warranty does
not cover electrical wiring.
5) The layout of power cable and signal cable should be orderly and not interfere with each
other.
CSwitch on after finishing all wiring construction and re-checking.
Pay attention to the following points:
1 The heat pump must be installed OUTSIDE in a well-ventilated area to avoid air
recirculation, or in a place with adequate room for both installation and maintenance.
Please refer to the following illustration for side fan models (PSNF50VS-PSNF65VS).
2 For top fan models (PSNF110VS-PSNF140VS), clearance above the unit should be 8’
unobstructed and 20’’ around.
A minimum of 20’ of clearance from walls, shrubbery, equipment, etc. is required around
the entire pump circumference. This allows for ample air intake. No less than 8’ clearance
on the air outlet is required to prevent recirculation of air. We recommend to not place the
unit underneath eaves, decks, or porches, as this causes recirculation of discharged air, or
the efficiency of the heater will be reduced or even stopped.