92
Advanced Setup View
Some additional preferences may be set in Advanced Setup View. This View is entered by holding
down Shift while powering the unit on, and exited by pressing Insert play icon Play.
The 8 x 4 grid is not illuminated in Advanced Setup View; adjustments are made using various
other buttons.
Easy Start Tool (Mass Storage Device)
The Easy Start Tool may be disabled in Advanced Setup View if you do not wish Circuit Rhythm to
appear as a Mass Storage Device when connecting it to a computer.
To toggle the Easy Start Tool on/off, press the Note button
6
. If Note is lit bright green, it is
enabled, if Note is lit dim red, it is disabled.
For more information on the Easy Start Tool, see page 8.
MIDI Thru configuration
You can determine the behaviour of the MIDI Thru port on Circuit Rhythm’s rear panel in Advanced
Setup View. The options are for the port to act as a regular MIDI Thru port (this is the default), or to
duplicate the output of the MIDI Out port. This is useful if you have two pieces of hardware that you
wish to control that don’t have MIDI thru ports themselves.
Use the Duplicate button
18
to set the behaviour. When Duplicate is lit bright green, the MIDI Thru
port will act as a second MIDI Out. When it is lit dim red, a hardware thru switch is activated and the
port acts as a regular MIDI Thru.
Master Compressor
Circuit Rhythm includes a master compressor, which is applied to all audio outputs from the device. It
can be enabled or disabled by pressing FX
12
while in in
Advanced Setup View. When the compressor
is enabled, the FX button lights bright green and the grid briefly displays ‘CMP’. When it is disabled,
the FX button lights dim red.

Table of Contents