12-21
LG : Lower Velocity Gain
Format : LG data
Data : 0 ~ 100 (%)
Shipping set : 0
Default : Not available
l Sets velocity loop proportional gain (VG) lowering ratio when IOFF input is activated.
l However, LG is invalidated when an excessive position error alarm is issued.
l The Motor does not generate torque if LG remains LG0 when IOFF turns ON.
« LO : Load Inertia
Format : LO data
Data range : 0.000 ~ 50.000 [kgm
2
]
Shipping set : 0
Default : 0
l This is to set the actual load inertia. The data may be entered when the load inertia is known prior
to perform automatic tuning.
The automatic tuning sets actual load inertia LO automatically.
l TS command or ?LO reports the current setting.
l Data of PG, VG, VI and MA will be automatically adjusted when LO data is changed.
l Data of LO is cleared to 0 when one of the data of PG, VG or VI is changed.
« LR : Low Torque Ripple
Format : LR data
Data range : 0, 1
Shipping set : 0
Default : 0
l Selects the characteristics of the Motor torque output.
0 : Standard
1 : Low torque ripple. (the maximum Motor torque will be lowered)
l “TS” or “?LR” command reports the current setting.