14-5
14.2.2.2. Abnormal Main AC Line Voltage
[Output] DRDY: Open
[TA] P1 > Main AC Line Trouble
[LED] P1
[Motor Condition] Servo-OFF
Table 14-4: Cause and Remedy: Abnormal main AC line voltage (Over/Under)
Cause Remedy
(1) Abnormal power supply voltage.
(2) Main circuit voltage is excessive due to high
acceleration/deceleration under heavy load.
Defective power source gives over AC250V
to the main power supply for power amplifier
main circuit.
(3) Defective power source gives under AC70V to
power amplifier main circuit.
Check main power supply.
(Excessive voltage, low voltage and power source
capacity.)
Check fuse, power source and the cable, then turn
power on again.
(4) Blown fuse.
(Motor over temperature, abnormal power
supply wiring, Driver Unit abnormal.)
Check blown fuse.
Check the fuse, power supply and cables, then turn
on power again.
(5) Excessive regeneration voltage. Readjust operation duty, the load and
acceleration/deceleration.
(6) Defective PCB.
(When the alarm is on after the Motor stops
even power source and fuse are normal.)
Replace Driver Unit.
Standard ESA Driver ----------- [Appendix 4]
Note : 1) When the regeneration dump resistor cannot process regenerative current, the voltage
of direct current to main circuit will be too high and the alarm will be on.
2) Decrease acceleration/deceleration.
14.2.2.3. Over Current
[Output] DRDY: Open
[TA] P2 > Over Current
[LED] P2
[Motor Condition] Servo-OFF
Table 14-5: Cause and Remedy: Over current
Cause Remedy
(1) Poor insulation of the Motor.
(Refer to “Appendix 2. How to Check Motor
Condition.”)
Replace Motor.
(2) Defective Motor Cable.
(Refer to “Appendix 2. How to Check Motor
Condition.”)
Replace Cable.
(3) Defective FET of Power Amplifier.
(When the alarm is on even the Motor and
Motor cable are normal.)
Replace Driver Unit.
Standard ESA Driver--------------------[Appendix 4]
Note : The alarm may be accompanied with abnormal main AC line voltage (blown fuse) alarm due
to excessive current flow.